I have a fluke DTX 1800 I can run a test on. It does gig e but I don't
remember what it does with a poe in the middle.

On Sat, Feb 13, 2016, 8:09 AM Mike Hammett <af...@ics-il.net> wrote:

> The best cable tester I've found is iPerf.
>
>
>
> -----
> Mike Hammett
> Intelligent Computing Solutions <http://www.ics-il.com/>
> <https://www.facebook.com/ICSIL>
> <https://plus.google.com/+IntelligentComputingSolutionsDeKalb>
> <https://www.linkedin.com/company/intelligent-computing-solutions>
> <https://twitter.com/ICSIL>
> Midwest Internet Exchange <http://www.midwest-ix.com/>
> <https://www.facebook.com/mdwestix>
> <https://www.linkedin.com/company/midwest-internet-exchange>
> <https://twitter.com/mdwestix>
> The Brothers WISP <http://www.thebrotherswisp.com/>
> <https://www.facebook.com/thebrotherswisp>
>
>
> <https://www.youtube.com/channel/UCXSdfxQv7SpoRQYNyLwntZg>
> ------------------------------
> *From: *"Forrest Christian (List Account)" <li...@packetflux.com>
> *To: *"af" <af@afmug.com>
> *Sent: *Saturday, February 13, 2016 8:02:30 AM
> *Subject: *[AFMUG] Gigabit "cable validator" which validates *through*
> a        Gigabit PoE Injector?
>
>
> Ok, everyone.....
>
> I'm looking for one or more Gigabit Ethernet testers to test product with
> which will actually test (signal-wise) a gigabit link for spec
> conformance.... The catch?  It has to work with a gigabit injector in the
> middle, since it's really about testing the injector's performance instead
> of a cable.
>
> Most of the gigabit cable validators I've seen will completely refuse to
> run the signal validation tests on a cable which doesn't pass electrical
> continuity.   Unfortunately, once you insert a gigabit injector the cable
> electrically looks like all 4 pairs are shorted, and there isn't any
> continuity to the far end.
>
> Does anyone have a CAT5 cable tester which works *through* a PoE?   Or are
> willing to test theirs on a (unpowered) injector to see what happens?
>
> --
> *Forrest Christian* *CEO**, PacketFlux Technologies, Inc.*
> Tel: 406-449-3345 | Address: 3577 Countryside Road, Helena, MT 59602
> forre...@imach.com | http://www.packetflux.com
> <http://www.linkedin.com/in/fwchristian>  <http://facebook.com/packetflux>
>   <http://twitter.com/@packetflux>
>
>

Reply via email to