Never saw it. Future units have a heavy duty packaging tape sticker over it.
Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Feb 24, 2016 8:15 AM, "Brandon Yuchasz" <li...@gogebicrange.net> wrote: > Well you guys caught that pretty fast. Wish we had back in summer when it > was put up. I can’t say I am happy about the amount of work that went into > dealing with their lack of quality on the product the only good news is it > failed before it ever had a customer on it. We tested and found 2.4 to weak > with the bare SMs. The Force units were not out yet so we didn’t deploy. I > didn’t even know it has burned until we got our first new 2.4 force and > tried to test it. Anyone else seen a similar issue? Just wondering if I > was lucky or if the sticker / covers on the LEDs get put on wrong often. > > > > > > Best regards, > > Brandon Yuchasz > > GogebicRange.net > > www.gogebicrange.net > > > > *From:* Af [mailto:af-boun...@afmug.com] *On Behalf Of *Mathew Howard > *Sent:* Tuesday, February 23, 2016 9:38 PM > *To:* af > *Subject:* Re: [AFMUG] Whats wrong with this picture? > > > > How would the water get out without sufficient ventilation? :p > > On Feb 23, 2016 9:23 PM, "Josh Luthman" <j...@imaginenetworksllc.com> > wrote: > > Too much ventilation. > > Josh Luthman > Office: 937-552-2340 > Direct: 937-552-2343 > 1100 Wayne St > Suite 1337 > Troy, OH 45373 > > On Feb 23, 2016 10:05 PM, "Brandon Yuchasz" <li...@gogebicrange.net> > wrote: > > What's wrong with this picture. Other than the fact that it's the end > result > of a half day of tower work and the unit was 100 feet in the air this > morning. > > Brandon >