That shit coming from Iowa last night looked pretty bad.
On 8/5/2016 11:14 AM, Mike Hammett wrote:
I feared the results of that storm. Didn't lose a thing.
-----
Mike Hammett
Intelligent Computing Solutions <http://www.ics-il.com/>
<https://www.facebook.com/ICSIL><https://plus.google.com/+IntelligentComputingSolutionsDeKalb><https://www.linkedin.com/company/intelligent-computing-solutions><https://twitter.com/ICSIL>
Midwest Internet Exchange <http://www.midwest-ix.com/>
<https://www.facebook.com/mdwestix><https://www.linkedin.com/company/midwest-internet-exchange><https://twitter.com/mdwestix>
The Brothers WISP <http://www.thebrotherswisp.com/>
<https://www.facebook.com/thebrotherswisp>
<https://www.youtube.com/channel/UCXSdfxQv7SpoRQYNyLwntZg>
------------------------------------------------------------------------
*From: *"Joe Novak" <[email protected]>
*To: *[email protected]
*Sent: *Friday, August 5, 2016 10:03:51 AM
*Subject: *Re: [AFMUG] residential cable preferences
+1 Shireen DC1021
Storms that rolled through a couple weeks ago took some Ethernet ports
with them of UBNT and EPMP. All of those installs where with
unshielded cable. *Shrugs* It was the worse electrical storm in a
couple years for us, so there is also that.
Joe
On Fri, Aug 5, 2016 at 9:10 AM, Ken Hohhof <[email protected]
<mailto:[email protected]>> wrote:
Not to start an ideological war, but FWIW, we don’t use shielded
cable at residential installs.
Typically we use Primus UTP. Have tried Apex9 with the reel in
the box, it’s less kinky but harder to pull from the box. We’re
using Shireen DC-1042 at towers now instead of Belden, so the
Shireen UTP should be fine also. If for some reason we wanted
shielded for residential, I assume we’d use the DC-1042.
*From:* That One Guy /sarcasm <mailto:[email protected]>
*Sent:* Friday, August 05, 2016 12:53 AM
*To:* [email protected] <mailto:[email protected]>
*Subject:* Re: [AFMUG] residential cable preferences
belden something or other was the greatest
but these mopes here where i work like apex 9, I think its utter
shit with its ultrathin foil and brittle copper
On Thu, Aug 4, 2016 at 11:44 PM, George Skorup <[email protected]
<mailto:[email protected]>> wrote:
Shireen DC-1021
On 8/4/2016 11:08 PM, Jay Weekley wrote:
I guess it's time for the regular survey on cable
preferences for residential installs. Of course looking
for shielded Cat5 and preferably pays out of a box.
--
If you only see yourself as part of the team but you don't see
your team as part of yourself you have already failed as part of
the team.