it would be better if it (450i) had on-board sync so i can power the whole
tower with one Netonix Switch and be done, but no i gotta mess around with
a CTM2 or Packet Flux Sync Injector now to get timing on 450i

On Tue, Aug 16, 2016 at 3:23 PM, George Skorup <[email protected]> wrote:

> As others have said, you obviously won't get sync from the Netonix. Plug
> the 450i *AP* in and go. It is 802.3at compliant, but it will also take
> passive injected power without issue. And you don't need to change any
> wires around. It will take either polarity on any pair. Cambium actually
> did this right. Woulda been even better if they designed for 20-60vdc, but
> I guess you can never have it all.
>
> Out of the 450i series, the only radio that is not 802.3at is the 900 SM
> which is the old Canopy 29.5v like FSK and regular 450.
>
> On 8/16/2016 12:18 PM, Darin Steffl wrote:
>
> Hello all,
>
> Will a Netonix 48V switch power the PMP450i 900mhz?
>
> I'm leaning towards that it will NOT due to needing 48-56V and 802.3at PoE
> which I don't think Netonix supports.
>
> Can anyone confirm my thoughts or tell me I'm wrong and it will work?
>
> Thanks
>
> --
> Darin Steffl
> Minnesota WiFi
> www.mnwifi.com
> 507-634-WiFi
> <http://www.facebook.com/minnesotawifi> Like us on Facebook
> <http://www.facebook.com/minnesotawifi>
>
>
>

Reply via email to