it would be better if it (450i) had on-board sync so i can power the whole tower with one Netonix Switch and be done, but no i gotta mess around with a CTM2 or Packet Flux Sync Injector now to get timing on 450i
On Tue, Aug 16, 2016 at 3:23 PM, George Skorup <[email protected]> wrote: > As others have said, you obviously won't get sync from the Netonix. Plug > the 450i *AP* in and go. It is 802.3at compliant, but it will also take > passive injected power without issue. And you don't need to change any > wires around. It will take either polarity on any pair. Cambium actually > did this right. Woulda been even better if they designed for 20-60vdc, but > I guess you can never have it all. > > Out of the 450i series, the only radio that is not 802.3at is the 900 SM > which is the old Canopy 29.5v like FSK and regular 450. > > On 8/16/2016 12:18 PM, Darin Steffl wrote: > > Hello all, > > Will a Netonix 48V switch power the PMP450i 900mhz? > > I'm leaning towards that it will NOT due to needing 48-56V and 802.3at PoE > which I don't think Netonix supports. > > Can anyone confirm my thoughts or tell me I'm wrong and it will work? > > Thanks > > -- > Darin Steffl > Minnesota WiFi > www.mnwifi.com > 507-634-WiFi > <http://www.facebook.com/minnesotawifi> Like us on Facebook > <http://www.facebook.com/minnesotawifi> > > >