show interface port shows it's fixed 1000,full,auto-off but when the port goes down it changes back to auto-on, I think that is a feature I read in the manual somewhere. Or maybe it's only when I remove the transceiver, it's been a long week, maybe that's normal?
On Wed, Oct 19, 2016 at 7:20 AM, Faisal Imtiaz <[email protected]> wrote: > Have you tried to put the "duplex full" command under the interface port > settings via the CLI ? > > I know changing it from the web interface does not keep the setting > 'persistently'. > > > Regards > > Faisal Imtiaz > Snappy Internet & Telecom > 7266 SW 48 Street > Miami, FL 33155 > Tel: 305 663 5518 x 232 > > Help-desk: (305)663-5518 Option 2 or Email: [email protected] > > ------------------------------ > > *From: *"TJ Trout" <[email protected]> > *To: *[email protected] > *Sent: *Wednesday, October 19, 2016 3:58:59 AM > *Subject: *[AFMUG] 1G/10G switch won't negotiate 1g on sfp > > I have a newly deployed ibm g8124 switch and all of the ports auto default > to auto negotiation if the port flaps, I have several 1G copper sfp, and > several 10G DAC/SFP that always work flawlessly but i have one single 1G > sfp that won't come up unless I manually disable auto negotiation then it > comes up fine until the next time the link goes down, is this something > that would likely be fixed buy firmware update or should I try another > model SFP? > >