Yes, the single blink seems like an overcurrent on port one.   The
questions I asked in the other thread might lead us to the cause.

On Mon, Mar 26, 2018, 12:02 PM George Skorup <george.sko...@cbcast.com>
wrote:

> IIRC, 1 flash = port #1 is tripped. 20 seconds sounds like boot up and
> then RF initialization puts it over the edge. That's pretty odd since Chuck
> has tested the GigE modules over 1A per pair. But the SS is obviously
> clamping if the port is tripping.
>
> On 3/26/2018 9:54 AM, Sam Lambie wrote:
>
> I sent a request to the list last week, but I think it got eaten but the
> list monsters.
> Last week, I installed a Cambium Medusa at one of my sites, replacing a
> 450 AP. I removed the APC surge suppressor and put in a gige HV model for
> the Medusa. It fires up, pings for about 20 seconds and then the whole
> SyncInjector looks like it shuts down. I get a 1 blink error code.
> When I take the SS out of the equation, it works fine. The only thing that
> I can think of is that the switch is a 2960 Cisco 10/100 and it can't
> handle the auto negotiation?
>
> Basic layout of Network back to Switch is this:
> Medusa > Cat6 100' (Tested at 1gig) > WBMFG APC SS > Packet Flux Gig
> SyncInjector powered by Traco  DIN rail PSU > Data out to Cisco 2960.
> Medusa is getting Sync from Sync Box Jr at Antenna location via Aux port
> (UGPS power enabled)
>
> Thanks!
> Sam
> --
> --
> *Sam Lambie*
> Taosnet Wireless Tech.
> 575-758-7598 Office
> www.Taosnet.com <http://www.newmex.com>
>
>
>

Reply via email to