To comment on the following update, log in, then open the issue: http://www.openoffice.org/issues/show_bug.cgi?id=63017
------- Additional comments from [EMAIL PROTECTED] Mon Mar 27 06:32:22 -0800 2006 ------- The logic when a series can be moved and when not depends not only on the index of the series. If a chart does contain multiple charttypes it is also important whether neighboured charttypes are compatible. The concrete logic is implemented in the method: DiagramHelper::moveSeries(). I strongly suggest to have only one implementation of this logic. So it would be good to enhance this method by a paramter which tells the method to indicate the possibility only or instead execute the move (bExecute for example). The return value than describes wheter a move is possible or wether it was actually done dependent on that input parameter. --------------------------------------------------------------------- Please do not reply to this automatically generated notification from Issue Tracker. Please log onto the website and enter your comments. http://qa.openoffice.org/issue_handling/project_issues.html#notification --------------------------------------------------------------------- To unsubscribe, e-mail: [EMAIL PROTECTED] For additional commands, e-mail: [EMAIL PROTECTED] --------------------------------------------------------------------- To unsubscribe, e-mail: [EMAIL PROTECTED] For additional commands, e-mail: [EMAIL PROTECTED]