To comment on the following update, log in, then open the issue: http://www.openoffice.org/issues/show_bug.cgi?id=65260
User af changed the following: What |Old value |New value ================================================================================ Status|NEW |STARTED -------------------------------------------------------------------------------- ------- Additional comments from [EMAIL PROTECTED] Thu May 11 05:16:49 -0700 2006 ------- The reason for the blank space below the slide is the Draw toolbar. This toolbar is marked as being non-context sensitive and therefore is managed by the framework layout manager, not the tool bar manager of Impress/Draw. The framework layout manager does not know about the fullscreen Consequently the tool bar is turned on when the fullscreen slide show is started. The canvas that is used for painting the slides can not handle the painting of tool bars and just shows a black area instead. --------------------------------------------------------------------- Please do not reply to this automatically generated notification from Issue Tracker. Please log onto the website and enter your comments. http://qa.openoffice.org/issue_handling/project_issues.html#notification --------------------------------------------------------------------- To unsubscribe, e-mail: [EMAIL PROTECTED] For additional commands, e-mail: [EMAIL PROTECTED] --------------------------------------------------------------------- To unsubscribe, e-mail: [EMAIL PROTECTED] For additional commands, e-mail: [EMAIL PROTECTED]