At Tue, 25 Feb 2003 07:43:59 -0800,
Mark Knecht wrote:
>
>
>
> > -----Original Message-----
> > From: [EMAIL PROTECTED]
> > [mailto:[EMAIL PROTECTED] Behalf Of Takashi Iwai
> > Sent: Tuesday, February 25, 2003 2:10 AM
> > To: Mark Knecht
> > Cc: Alsa-Devel
> > Subject: Re: [Alsa-devel] kaconnect question and enhancement request
> >
> > no idea.. doesn't aconnect in alsa-utils work?
> >
>
> Takashi-san,
> Thanks. I tried aconnect, and read through the --help stuff, but couldn't
> figure out the command to hook together two ports. Could you give an
> example? Everything I tried resulted in error messages.
try "man aconnect" :)
i think there are some online documents about this, too.
suppose you having the sequencer ports 64:0 and 64:32.
for connecting between the same input and output, just run like
% aconnect 64:0 64:0
>
> I also wondered about hooking a single input to multiple outputs, so if
> you could show an example of that, I would appreciate it.
call aconnect several times,
% aconnect 64:0 64:0
% aconnect 64:0 72:0
for removing the connection, use -d option,
% aconnect -d 64:0 64:0
basically, kaconnect does these things in GUI.
hence, if aconnect doesn't work, likley kaconnect won't work, too.
ciao,
Takashi
-------------------------------------------------------
This sf.net email is sponsored by:ThinkGeek
Welcome to geek heaven.
http://thinkgeek.com/sf
_______________________________________________
Alsa-devel mailing list
[EMAIL PROTECTED]
https://lists.sourceforge.net/lists/listinfo/alsa-devel