Stefan Mueller found a bug in my Digi96 driver. Sometimes I write !=
when I mean == or the other way around:
--- rme96.old.c 2003-07-01 20:13:40.000000000 +0200
+++ rme96.new.c 2003-07-01 20:13:26.000000000 +0200
@@ -1318,7 +1318,7 @@
snd_pcm_set_sync(substream);
runtime->hw = snd_rme96_capture_adat_info;
- if (snd_rme96_getinputtype(rme96) != RME96_INPUT_ANALOG) {
+ if (snd_rme96_getinputtype(rme96) == RME96_INPUT_ANALOG) {
/* makes no sense to use analog input. Note that analog
expension cards AEB4/8-I are RME96_INPUT_INTERNAL */
return -EIO;
-------------------------------------------------------