> > ---/var/log/messages---
> > Feb 20 04:19:39 fordprefect kernel: scsi : aborting command 
> due to timeout :
> > pid 1653712, scsi0, channel 0, id 2, lun 0 Write (6) 01 00 00 40 00
> > Feb 20 04:19:41 fordprefect kernel: SCSI host 0 abort (pid 
> 1653712) timed
> > out - resetting
> > Feb 20 04:19:41 fordprefect kernel: SCSI bus is being reset 
> for host 0
> > channel 0.
> > Feb 20 04:19:44 fordprefect kernel: (scsi0:0:2:0) 
> Synchronous at 40.0
> > Mbyte/sec, offset 8.
> > Feb 20 04:19:44 fordprefect kernel: st0: Error with sense 
> data: [valid=0]
> > Info fld=0x0, Current st09:00: sense key Unit Attention
> > Feb 20 04:19:44 fordprefect kernel: Additional sense 
> indicates Power on,
> > reset, or bus device reset occurred
> > ---/var/log/messages---
> > 
> > Does someone know, how to fix?
> 
> You should check SCSI cabling and terminators..
> Can you describe your SCSI setup (cable length, adapters, 
> internal/external
> devices, ...) ?
> -- 
>    Rémy Chibois
> 

Adapter is an AHA2940U2W, only internaly connected to the ADR50i.
So cable length ca. 30cm. - SCSI cabling and terminator are OK.

---mt status---
drive type = Generic SCSI-2 tape
drive status = 512
sense key error = 0
residue count = 0
file number = 0
block number = 0
Tape block size 512 bytes. Density code 0x0 (default).
Soft error count since last status=0
General status bits on (41010000):
 BOT ONLINE IM_REP_EN
---mt status---

The ADR50-Device is configured as follows:
---amanda.conf---
define tapetype ADR50 {
    comment "ADR50 tape drives"
    length 50000 mbytes        # 50 Gig tapes
    filemark 2000 kbytes       # I don't know what this means
    speed 14336 kbytes         # 14 MB/s
}
---amanda.conf---

Reply via email to