I was having problems similar to this (though I can't remember the
specific error messages).  I'm using chg-zd-mtx on Solaris 8 with
an Overland LoaderXpress (DLT).  What solved the problem for me
was making sure that the changer config file has _all_ of the
variables specified, even if they seemed to be default values.
The chg-zd-mtx script doesn't seem to set default values, and gives
weird errors if they're not there.

  --rowan

Lo, Donnie Emeson and the coffee pot sang in unison:
> I'm having trouble with amanda 2.4.2p2 and a new changer, a Sun L20 with
> 20 slots and one DLT8000.
> 
> This changer has a barcode reader, but I'm not using it.  (I don't have
> a label maker and don't really want to bother.)  Perhaps this is what's
> causing my problems...
> 
> I have chg-zd-mtx working, though I had to make some minor changes.
> 
> The problem is amlabel and amcheck.  Both get similar errors.  Amlabel
> goes ahead and loads the first tape and then gives me:
> amlabel: could not load slot "current": badly formed result from changer: 
>"MT=/usr/bin/mt"
> 
> Amcheck is fine except for this error:
> amcheck-server: could not get changer info: badly formed result from changer: 
>"MT=/usr/bin/mt"
[snip]

-- 
John "Rowan" Littell
Systems Administrator
Earlham College Computing Services

PGP signature

Reply via email to