Hi Marc,

the file  sendsize.20070828155152.debug  says:

sendsize: debug 1 pid 7226 ruid 5000 euid 5000: start at Tue Aug 28 15:51:52 2007
sendsize: version 2.5.2p1
Reading conf file "/usr/local/etc/amanda/amanda-client.conf".
Reading conf file "/usr/local/etc/amanda/daily/amanda-client.conf".
sendsize: debug 1 pid 7226 ruid 5000 euid 5000: rename at Tue Aug 28 15:51:52 2007
sendsize[7226]: time 0.003: waiting for any estimate child: 1 running
sendsize[7228]: time 0.003: calculating for amname /Users/amanda/ sync, dirname /Users/amanda/sync, spindle -1 sendsize[7228]: time 0.003: getting size via dump for /Users/amanda/ sync level 0 sendsize[7228]: time 0.004: calculating for device /Users/amanda/sync with sendsize[7228]: time 0.004: running "/sbin/dump 0sf 1048576 - /Users/ amanda/sync"
sendsize[7228]: time 0.005: running /usr/local/libexec/killpgrp
sendsize[7228]: time 0.009: DUMP: Date of this level 0 dump: Tue Aug 28 15:51:52 2007
sendsize[7228]: time 0.009:   DUMP: Date of last level 0 dump: the epoch
sendsize[7228]: time 0.009: DUMP: Dumping /Users/amanda/sync to standard output
sendsize[7228]: time 0.081:   DUMP: bad sblock magic number
sendsize[7228]: time 0.081:   DUMP: The ENTIRE dump is aborted.
sendsize[7228]: time 0.082: .....
sendsize[7228]: time 0.082: estimate time for /Users/amanda/sync level 0: 0.077 sendsize[7228]: time 0.082: no size line match in /sbin/dump output for /Users/amanda/sync
sendsize[7228]: time 0.082: .....
sendsize[7228]: time 0.082: Run /sbin/dump manually to check for errors
sendsize[7228]: time 0.082: asking killpgrp to terminate
errmsg is no size line match in /sbin/dump output
sendsize[7228]: time 1.082: done with amname /Users/amanda/sync dirname /Users/amanda/sync spindle -1
sendsize[7226]: time 1.082: child 7228 terminated normally
sendsize: time 1.083: pid 7226 finish time Tue Aug 28 15:51:53 2007

Thanks for your help
Maya





On 28 Aug 2007, at 13:43, Marc Muehlfeld wrote:

Hi,

Maya Bercovich schrieb:
myclient.mydomain.com /Users/amanda/sync lev 0 FAILED [no size line
match in /sbin/dump output]

What does sendsize*.debug file on your client says?

Regards
Marc


--
Marc Muehlfeld (Leitung Systemadministration)
Zentrum fuer Humangenetik und Laboratoriumsmedizin Dr. Klein und Dr. Rost
Lochhamer Str. 29 - D-82152 Martinsried
Telefon: +49(0)89/895578-0 - Fax: +49(0)89/895578-78
http://www.medizinische-genetik.de


Reply via email to