Brian,

Maybe you defined the tape larger than it is?
Are you sure the tape can hold 800000M of data?
Are you using hardware compression?

Jean-Louis

On 01/08/2014 09:13 AM, Brian Cuttler wrote:
I'm not sure I understand this tape usage... 18% plus 75% < 100%, isn't it?

Amanda 3.3.0
Solaris 10x86
tapes are DLT IV

This, using a second tape, is new behaivor.

I did try a newer amanda but the dump clients wouldn't die when
they needed two, amanda never completed and required a lot of
daily manual cleanup. I haven't tried the latest...


FAILURE DUMP SUMMARY:

   finsen / lev 0  partial taper: No space left on device, splitting not 
enabled  finsen / lev 0  was successfully re-flushed

USAGE BY TAPE:
   Label               Time         Size      %  DLEs Parts
   Finsen32            2:57      603197M   75.1    17    17
   Finsen33            0:48      145593M   18.1   259   259