Ok, thanks for the tip:

[root@ulysses ~]# su amandabackup -c '/usr/sbin/amtape Mensuel-LTO7 verify'
GOOD : Drive 0 is device tape:/dev/nst1
GOOD : Drive 1 is device tape:/dev/nst0
property "TAPE-DEVICE" "0=tape:/dev/nst1" "1=tape:/dev/nst0"

Best regards, Luc.


On 2018-01-15 08:10 AM, Jean-Louis Martineau wrote:
Luc,

The assignment of 'Data Transfer Element 0' to '/dev/nst1' and 'Data
Transfer Element 1' to '/dev/nst0' is done by the kernel.

You can use the 'amtape CONF verify' command to check if you correctly
configured amanda.

Jean-Louis


On 13/01/18 06:40 PM, Luc Lalonde wrote:
> Hello Folks,
>
> I’m getting a strange result when I do an ‘amcheck’:
>
> slot 3: Tape device /dev/nst1 is not ready or is empty
> slot 4:Slot 4, label '000279L7', mismatch barcode between changer '000280L7' and tapelist file '000279L7' > ERROR: Slot 4, label '000279L7', mismatch barcode between changer '000280L7' and tapelist file ‘000279L7'
>
> Here’s what I have in my config file:
>
> define changer spectra-robot {
> tapedev "chg-robot:/dev/changer"
> property "tape-device” "0=tape:/dev/nst0"
> property append "tape-device” "1=tape:/dev/nst1"
> device-property "BLOCK_SIZE" "512k"
> property "use-slots" "1-47”
> }
>
> To get rid of the problem, I reverse the tape device order:
>
> define changer spectra-robot {
> tapedev "chg-robot:/dev/changer"
> property "tape-device" "1=tape:/dev/nst0"
> property append "tape-device" "0=tape:/dev/nst1"
> device-property "BLOCK_SIZE" "512k"
> property "use-slots" "1-47”
> }
>
> Here’s the pertinent lines of the ‘amcheck’ after having made this change:
>
> slot 3: volume '000279L7'
> Will write to volume '000279L7' in slot 3.
>
> What going on? If it can help, here’s the output of ‘lsscsi -g’ (I removed the non-tape + changer lines):
>
> [1:0:4:0] tape IBM ULTRIUM-HH7 G9Q1 /dev/st0 /dev/sg10
> [2:0:4:0] tape IBM ULTRIUM-HH7 G9Q1 /dev/st1 /dev/sg13
> [2:0:4:1] mediumx SPECTRA PYTHON 2000 /dev/sch0 /dev/sg14
>
> And here’s an output of the first few lines of the command ‘mtx status’:
> Data Transfer Element 0
>
> Storage Changer /dev/changer:2 Drives, 48 Slots ( 1 Import/Export )
> Data Transfer Element 0:Empty
> Data Transfer Element 1:Full (Storage Element 3 Loaded):VolumeTag = 000279L7
> Storage Element 1:Full :VolumeTag=000277L7
> Storage Element 2:Full :VolumeTag=000278L7
> Storage Element 3:Empty
> Storage Element 4:Full :VolumeTag=000280L7
>
> I’m using a 50 slot SpectraLogic T50e library with two LTO7 IBM drives.
>
> Thanks!
>
>
>
>
>


*Disclaimer*

This message is the property of *CARBONITE, INC.* <http://www.carbonite.com> and may contain confidential or privileged information.

If this message has been delivered to you by mistake, then do not copy or deliver this message to anyone. Instead, destroy it and notify me by reply e-mail.


--
Luc Lalonde, analyste
-----------------------------
Département de génie informatique:
École polytechnique de MTL
(514) 340-4711 x5049
luc.lalo...@polymtl.ca
-----------------------------

Reply via email to