On 7/21/21 9:20 PM, Evan Quan wrote:
The customized OD settings can be divided into two parts: those
committed ones and non-committed ones.
- For those changes which had been fed to SMU before S3/S4/Runpm
suspend kicked, they are committed changes. They should be properly
restored and fed to SMU on S3/S4/Runpm resume.
- For those non-committed changes, they are restored only without feeding
to SMU.
Change-Id: Iea7cf7908dfcd919a4d0205e10bff91b1149a440
Signed-off-by: Evan Quan <evan.q...@amd.com>
---
It's been a while since I've been through the SMU code so I don't know
all the places that restore_uesr_profile is used, but, just to confirm,
these would still go back to default (boot) values on a GPU reset, yes?
I ask because when pushing OD settings too far, GPU resets are often
encountered, and you might be able to create a state where it would
continually reset if your OD settings are remembered even through a full
reset.
Very nice feature other than that, though, as I actually keep
`radeontop` open in a tmux session to prevent my secondary card from
resetting my OD settings, so this will be nice.
Thanks for listening, and for the driver in general,
Matt