On Sun, Jan 30, 2011 at 5:53 PM, Dennis Cartier <[email protected]>wrote:

>
> Pito, I have pretty much the same thing (except for freq, and baud). I
> noticed that you hard coded the device.asm where as mine did not have a
> path. It did not seem to make a difference when I tried hard coding it
> though.
>
> One thing that did jump out at me, you have a 22Mhz clock on your
> atmega1284p?
>
> I moved my baud in the template.asm back up to 9600 and now I get 1200
> baud. It always seems to 1/4 of the requested baud.
>
> Dennis
>
>
After I read my last email, I realized the issued.9600/1200 = 8 not 4. That
made me realize that the /8 clock pre-scaler bit was set. Toggled that off
and all good now.

Now I just have 30 years since I last used Forth to overcome. :)