I've begun recapping the Viking II I'm working on.  The dual 15Uf/150V cap 
connected to the 6AL5 has the positive sides of the cap going to the 6AL5 and 
choke and the negative side going to ground.  Since this guy is intended to 
produce negative voltage and the connection is to the plates of the 6AL5 rather 
than the cathodes, shouldn't the filter caps (I'm using two 22Uf/450V) positive 
side be going to ground and the negative sides going to the 6AL5 plates?

I'm reasonably certain this is correct, but the original design used a dual 
(two caps in one package with a common ground lead) cap and I've never seen one 
where the common lead wasn't the negative sides of the electrolytic cap. 

Thanks for your advice.

arnie - W1GCI