The paexec.exe is being called by both the AL and the Escalation.  It just 
isn't working the same as it does on my 7.5 server.  Paexec creates the 
remote process and the command is run on the remote machine, but it doesn't 
remove the remote process and doesn't return the value.
It works if I run it from a command line and call the exe on the remote 
server.

On Friday, August 21, 2015 at 12:17:53 PM UTC-4, Grooms, Frederick W wrote:
>
> Since it is failing as an Escalation as well then it is not encountering 
> the Active Link Run Process directory security setting in the Admin Console 
>
> I don’t have any v9 servers up right now so I'm not sure what is trying to 
> run. 
>
> Fred 
>
> -----Original Message----- 
> From: jham36 [mailto:jha...@gmail.com <javascript:>] 
> Sent: Friday, August 21, 2015 10:24 AM 
> To: Remedy ARS 
> Cc: ars...@arslist.org <javascript:>; Grooms, Frederick W 
> Subject: Re: Remedy 9 PROCESS command 
>
> My Active Link is actually a test for what is really done as an 
> Escalation.  I need to call the exe to return a status value.  I created an 
> Active Link and attached it to a button in order to test.  It is failing as 
> an AL and as an Escalation. 
>
> -----Original Message----- 
> On Thursday, August 20, 2015 at 5:58:51 PM UTC-4, Grooms, Frederick W 
> wrote: 
> ** 
> I’m always leery of running a server side command from an AL.  I now do 
> the following 
>   
> Create a SERVICE type filter to run the command. 
> Call the Filter from the AL with the Service action (and in here you can 
> return the values you want) 
>   
> Fred 
>   
> -----Original Message-----  
> From: Action Request System discussion list(ARSList) [mailto:
> ars...@arslist.org <javascript:>] On Behalf Of jham36 
> Sent: Thursday, August 20, 2015 4:44 PM 
> To: ars...@arslist.org <javascript:> 
> Subject: Remedy 9 PROCESS command 
>
> ** 
> Hello all, 
>
> A few months ago I posted an issue about running psexec from Remedy and 
> got some good help.  I ended up using paexec which is able to get the 
> console output from the remote process and return it directly into remedy. 
> I am currently on ARS 7.5 and upgrading to ARS 9 and doing some testing on 
> the new servers.  What I have is an Active Link doing a set fields 
> $PROCESS$ @@:$StatusCommand$ $Test Set Name$ 
> I am getting values from fields on the form to use in the Process command. 
>  The path to paexec.exe plus parameters and the remote exe name and 
> parameters. 
>
> D:\QCInt\PAExec\paexec.exe \\servername -u domain\User -p Password 
> C:\User\QCInt\RunTestSet\RunTestSet.exe -ss Demo_Process 
>
> I didn't have to call cmd.exe or comspec or anything special. 
>
> This works fine with my ARS 7.5 system and I get the return value into 
> Remedy. 
> On my new ARS 9 system, the remote process is executed, but I do not get 
> the return value and the paexec process as well as the remote temporary 
> paexec service do not exit. 
> When I run the same command from a command line on the new remedy server, 
> it works just fine. 
> It seems that something has changed in how the $PROCESS$ command works. 
>
> Any ideas? 
>
> Thanks, 
> James 
>
> _______________________________________________________________________________
>  
>
> UNSUBSCRIBE or access ARSlist Archives at www.arslist.org 
> "Where the Answers Are, and have been for 20 years" 
>

_______________________________________________________________________________
UNSUBSCRIBE or access ARSlist Archives at www.arslist.org
"Where the Answers Are, and have been for 20 years"