Hi, The release notes says that the Error Messages has been improved and better documented.
In my investigations of differences between 7.6.03 and 7.6.04 I see that 39 message numbers has been added and that 78 has been removed, but the file {installdir}/help/errars.arx has been increased in size. One interesting thing is that the following message has been removed both in errars.arx and in the Error Message Guide for 7.6.04: ARERR [30] You are already at the limit of the number of fixed user licenses of the following type : Write : (3) I tried this, but it still gives me the same error in the new system... I have added the full list of both Removed and Added messages to the end of this email. Best Regards - Misi, RRR AB, http://www.rrr.se Products from RRR Scandinavia (Best R.O.I. Award at WWRUG10): * RRR|License - Not enough Remedy licenses? Save money by optimizing. * RRR|Log - Performance issues or elusive bugs? Analyze your Remedy logs. Find these products, and many free tools and utilities, at http://rrr.se. ######## Removed messages between 7.6.03 and 7.6.04 ######## 30 - You are already at the limit of the number of fixed user licenses of the following type licenseType. 86 - No support for indexing in the flat file database -- index definition is stored but not implemented. 87 - The flat file server is approaching the maximum file size limit (no submissions are allowed after the limit is reached). 88 - No support for direct SQL commands in the flat file database. 89 - No support for join form data calls in the flat file database -- join form definition is stored but cannot be used. 280 - AR System entry calls to join forms are not supported in a Flat File database. 362 - The flat file server has hit the maximum file size limit. No more entries can be created. 500 - Failure while trying to open the flat file database data file (check Server-directory setting). 501 - The specified flat file database file is not a valid data file. 502 - Flat file database format error. 503 - Failure during write to flat file database data file. 505 - Error encountered with the flat file database form file (schema.ar). 506 - Error encountered with the flat file database definition file (xxx.def). 507 - Error encountered with the flat file database data file (xxx.db). 508 - Error encountered with the flat file database filter file (filter.ar). 510 - Error encountered with the flat file database user cache file (user.ar). 511 - Error encountered with the flat file database group cache file (group.ar). 512 - Error encountered with the flat file database active link file (actlink.ar). 513 - Flat file database data record overflow. 514 - Contents of the Status-History field in the flat file database are missing or invalid. 515 - Error encountered with the flat file database character menu file (charmenu.ar). 516 - Error encountered with the flat file database escalation file (escl.ar). 517 - Error encountered with the flat file database support file (supfile.ar). 518 - Error encountered with the flat file database support detail file. 520 - Error encountered with the flat file database attachment BLOB file. 521 - Error encountered with the flat file database attachment BLOB file index. 522 - Error encountered with the flat file database alert user file (alertusr.ar). 523 - Error encountered with the flat file database alert time file (alerttim.ar). 3502 - The variable associated with this alarm has been deleted. A variable should be associated for this alarm to work. 3503 - There are no variables in this server. Please create a variable before creating an alarm. 3506 - Provide a name for the data source. 3507 - You must add at least one variable to save a data source. 3508 - Group access is not defined -- only the administrator has access to this data source. 3510 - You must associate a data source name with the flashboard. Select one from Configuration tab. 3511 - The data source you selected does not contain any variables. Select a data source with variables. 3512 - No data source has been defined. At least one data source is required to define a valid flashboard. 3513 - End Date and Time should be greater than Start Date and Time. 3514 - One of more variables have been deleted from the selected datasource since this flashboard was saved. 3516 - You cannot select the start time greater than/same as end time. 3605 - Invalid Flashboard Data Source: Statistic and History Variables should not be mixed together. 3608 - You have exceeded the allowed usage of Flashboards. Please obtain a license if you wish to continue using Flashboards. 3612 - User has no access permission to Flashboards data source: dataSource. 3613 - There was no valid Datasource for this Flashboard. 4100 - %s\nUsage: %s [-x server] [-m mapping-name] [-d startup-directory] [-b] 4152 - No tokens for a Direct Mapping. 4162 - Bad internal list. 4170 - Bad Form Information UI Fields list. 4188 - The import field separator string is longer than the maximum allowed length. 4821 - TGP specified in data, but no group form. 4837 - Catalog command requires form to be the parts form. 4838 - Malloc failed in Purchase Request server. 4839 - The part record does not have a parent category. 4840 - A category was specified that does not exist. 4841 - Error while attempting to open a parts catalog file. 4842 - Part type value is unrecognized. 4843 - Row count on part is inconsistent with definition of part. 4844 - Line Item Map command requires form to be the purchase request form. 4846 - A value for Supplier for each line is required to split line items. 4847 - Line Item Mapback command requires form to be the line item form. 4848 - No line number field or field contains a bad value for line item. 4849 - No purchase request ID field or field contains a bad value for line item. 4850 - Pending ID is required when run in one command mode. 4851 - Failure while splitting line items from the purchase requisition. 4852 - Failure while updating a line item in the purchase requisition. 4853 - Command requires entry ID. 4854 - Command requires entry ID, tag, and other. 4855 - Command requires form and entry ID be specified. 4856 - Could not find the Purchase Requisition-Line Item form. 4857 - Line item index out of bounds for this Purchase Requisition. 5383 - Invalid alarm variable. A variable with the given name does not exist. 5386 - Alarm variable variableName does not exist. 5387 - Alarm variable variableName is invalid and might not exist. 5388 - Alarm variable variableName is invalid. It might not exist or the server might not be able to retrieve it. See the following messages. 8729 - Vendor forms not allowed in join forms. 8808 - The specified flat file database file is not a valid container file. 8813 - Error encountered with the flat file database container file (contain.ar). 9279 - Not a valid license for web tier to access the server: serverName. 9346 - Failed to deploy. Make sure the form - formName and the view - viewName have an alias name. ######## Added messages between 7.6.03 and 7.6.04 ######## 671 - The indexer for running the Full Text Search indexing cannot be found. 681 - Due to the field length change, the corresponding full text index is being rebuilt. 3132 - Two forms contain all the reserved distributed logical mapping fields -- delete one to continue. 3133 - No Distributed Logical Mapping form could be found on the server. 3134 - Logical name %s is not found in logical mapping form. 5312 - nameOfOperation operation not allowed on specified object. reasonOperationIsNotAllowed. 5317 - nameOfOperation operation not allowed on specified object. reasonOperationIsNotAllowed. 5318 - Fields on View nameOfView has invalid Z order. Overlay of View required to modify it. 5319 - Field nameOfField has missing layout information. Overlay of View required to modify it. 5321 - View nameOfView has no label. Overlay of View required to modify it. 5322 - Can not use Form nameOfForm as remote form because it does not contain fields referred by columns or cell fields in the overlaid form. 5323 - Creating new object is not allowed in Best Practice Customization Mode since AR System Server version is less than 7.6.04. Please use Base Development Mode to create new objects. 5324 - Creating objectType is not allowed in Best Practice Customization Mode. Please use Full Development Mode to create new objectType. 5327 - Only custom fields can be added from a base form to an Overlay join form. 5328 - The objectType 'objectName' has an open editor. Overlay cannot be created for objects that are currently opened in editor. 8856 - An overlay and its corresponding overlaid object cannot belong to the same overlay group. 8857 - Creating overlay is not supported for the type of object specified. 8858 - __C and __O are system reserved suffix and cannot be added manually. 8859 - Invalid operation on overlay or overlaid object. 8860 - The Group ID for Overlay and custom objects can only be 0 (does not belong to an overlay group) or 1 (belongs to the overlay group). 8861 - Base and overlay object should be of same type. 8863 - Before creating an overlay of a field or a form view, you must create an overlay of the object's associated form. 8864 - Invalid value for overlay property. 8865 - Field/View overlay and the associated base form overlay must be in the same overlay group. 8866 - Audit/Archive form overlay and the associated base form overlay must be in the same overlay group. 8867 - Unable to find overlay for specified overlaid object. 8868 - Field overlay and the associated view overlay must be in the same overlay group. 8869 - To convert custom field to overlay, field ID of custom and base must be the same. 8870 - To convert custom field to overlay, custom form name and the base form name must be the same. 8871 - Field must be of custom type on given form. 8872 - Unable to find the overlaid object. 8873 - Renaming of overlay object is not allowed. 8874 - Object is not a valid custom object, hence cannot be converted to base. 8875 - Audit or archive form must be custom for the specified overlay form. 8876 - The object is either custom or overlay object and converting it to custom or overlay in same overlay group is not allowed. 8879 - Base object and custom object names are same. Conversion of custom to overlay is not allowed. 9302 - Throw Error - 9302. 9426 - An error had occurred. Please see your administrator. 20000 - Use the 20000-20999 range for externally written plug-in messages. _______________________________________________________________________________ UNSUBSCRIBE or access ARSlist Archives at www.arslist.org attend wwrug11 www.wwrug.com ARSList: "Where the Answers Are"