This will be included in 8.1 Service Pack 01. i.e. scheduled tentatively 
November this year (subject to change)

From: Action Request System discussion list(ARSList) 
[mailto:arslist@ARSLIST.ORG] On Behalf Of Jason Miller
Sent: Thursday, September 12, 2013 8:12 PM
To: arslist@ARSLIST.ORG
Subject: Re: Problem with ARInput in Spoon

**
Thanks Kiran for informing us about this bug!  I was fighting this a few months 
ago with a process that I put aside but need to get back to.  Is there a hotfix 
available or any indication of version/patch this bug will be fixed in?

Jason

On Thu, Sep 12, 2013 at 7:08 AM, Hullule, Kiran 
<kiran_hull...@bmc.com<mailto:kiran_hull...@bmc.com>> wrote:
**
Looks like a known bug?  # SW00453874

As a workaround can you try the workaround mentioned in attached example.  Step 
C

HTH

From: Action Request System discussion list(ARSList) 
[mailto:arslist@ARSLIST.ORG<mailto:arslist@ARSLIST.ORG>] On Behalf Of Mitcham, 
Ross
Sent: Thursday, September 12, 2013 6:36 PM
To: arslist@ARSLIST.ORG<mailto:arslist@ARSLIST.ORG>
Subject: Re: Problem with ARInput in Spoon

**
What is the Step before the ARInput step?

From: Action Request System discussion list(ARSList) 
[mailto:arslist@ARSLIST.ORG<mailto:arslist@ARSLIST.ORG>] On Behalf Of John 
Marshall
Sent: Thursday, September 12, 2013 8:38 AM
To: arslist@ARSLIST.ORG<mailto:arslist@ARSLIST.ORG>
Subject: Problem with ARInput in Spoon

**
Hello All,
I am setting up a transformation in Spoon and I am trying to use the ARInput 
step however when I go to setup the Qualification and go to 'Configure 
Qualification' my list of Stream Fields is blank (this is after setting up 
connection to my ARS server and having another step hopping to this one). If I 
right click on the ARInput step and select 'Show Input Fields' I see the list 
of upstream fields that I would expect to see in stream fields section in the 
configure qualification. I have setup another system and the same behavior 
exists.
I have checked out the online wiki page for this and it says that "If variables 
are used in the qualification string, the ARInput step will use the variable 
values at runtime." So that would lead me to believe you can use upstream 
fields.
I have created a ticket with BMC (over a month ago) and I have yet to receive 
any help there.
So I am hoping someone here can help me out.
Thanks in advance for any help/suggestions

John

Environment: ARS/ITSM 8.1 Patch 1 (also happened on non-patched), Windows 2008 
R2 w/ MS SQL 2008 R2. Also using Spoon 4.1.0 on Windows (various flavors)
_ARSlist: "Where the Answers Are" and have been for 20 years_
_ARSlist: "Where the Answers Are" and have been for 20 years_
_ARSlist: "Where the Answers Are" and have been for 20 years_

_ARSlist: "Where the Answers Are" and have been for 20 years_

_______________________________________________________________________________
UNSUBSCRIBE or access ARSlist Archives at www.arslist.org
"Where the Answers Are, and have been for 20 years"

Reply via email to