I’m taking a snapx dump of the SDWA don’t want to get involved with EREP



> On Jul 8, 2020, at 1:43 PM, Charles Mills <charl...@mcn.org> wrote:
> 
> Me, personally? It does not ring a bell.
> 
> I have an atypical debugging approach. I avoid dumps if at all possible. I 
> have other approaches -- too long a story for a mailing list e-mail -- that 
> work for me.
> 
> In the product I fairly recently developed and supported yes, in the event of 
> an ESTAEX or FRR exit, we formatted some SDWA fields and logged them. I don't 
> see SDWARBAD in there.
> 
> Charles
> 
> 
> -----Original Message-----
> From: IBM Mainframe Assembler List [mailto:ASSEMBLER-LIST@LISTSERV.UGA.EDU] 
> On Behalf Of Joseph Reichman
> Sent: Wednesday, July 8, 2020 10:21 AM
> To: ASSEMBLER-LIST@LISTSERV.UGA.EDU
> Subject: Re: Finding abending PSW and registers
> 
> Finding the right registers is the most important thing in recovery specially 
> if you do a retry 
> Charles have you ever used SWDARBAD ( when available to find the program 
> registers looking for your program name in CDNAME )

Reply via email to