I assume you mean condition code should be 1, and I'd agree.  Are you sure the 
length is correct and you're not accidentally including some other storage?

Jonathan Scott

-----Original Message-----
From: IBM Mainframe Assembler List <[email protected]> On Behalf 
Of Joseph Reichman
Sent: 17 February 2026 16:29
To: [email protected]
Subject: TP instruction

I am using tso TEST For a field of binary zeros Shouldn’t the condition code be 
4 

Pops book says
0 all digits and sign are valid
1 sign invalid
2 at least 1 digit code invalid
3 Sign invalid and at least 1 digit code invalid 

Doing a list PSW after the TP shows the CC column with 11

For binary zeros only the sign is invalid 