It's not clear whether you're assuming 31-bit or 64-bit mode. If it's only 31-bit, then IILF (also known as LFI if you have a recent maintenance level of HLASM) would probably be best as a hardware solution, and you can write the immediate value as follows if you like:
LFI R15,C' '*X'1000000' Jonathan Scott -----Original Message----- From: IBM Mainframe Assembler List <[email protected]> On Behalf Of Mark Hammack Sent: 05 March 2026 20:32 To: [email protected] Subject: Loading the pad byte for MVCL So, I was wondering if anyone had a "better" way. I've done: IC R15,C' ' SLL R15,24 and LGFI R15,X'40000000' and LY R15,PADCHAR ... PADCHAR DC C' ',X'000000' What I'd like is to do something like the LGFI (or LLILH) but using the more "self documenting" PADCHAR format. I'm probably just too picky. I could probably write a SETPAD macro and use SLL, just haven't tried that yet. *Mark Hammack* [email protected]