Put up a hard loop at the switch toward the asterisk system. If it doesn't sync up and clear the red alarm, replace the wiring.
-Paul Barry O'Donovan wrote: > Hi Paul, > > On Wednesday 23 April 2008 20:57:40 Paul Timmins wrote: > >> Your T1 is in red alarm and doesn't have frame alignment. That's usually >> a problem for establishing SS7. :) >> > > Any pointers on getting it into alignment? > > These same wanpipe settings (with a DCHAN) worked perfectly as a PRI > interface > to the same switch (and yes - we have moved to a SS7 "port" on the switch > now). > > > - Barry > _______________________________________________ --Bandwidth and Colocation Provided by http://www.api-digital.com-- asterisk-ss7 mailing list To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-ss7