On Jan 10, 2011 9:59 AM, "Wasim Baig" <[email protected]> wrote:
>
> On Sun, Jan 9, 2011 at 23:18, Benaiad <[email protected]> wrote:
>>
>> Hi,
>>
>> ;First of all, I'm newbie in this field, so please forgive
my unprofessional explanation.
>>
>>
>> I'm trying to connect to a mobile operator with chan_ss7 using sangoma
card.
>> the telecom regulator initiated an SPC code for us
>> Now, the operator's engineer asked me for the following parameters:
>> OPC , Link type , TS , SLC.
>
>
> Ideally, they should give a Point Code for you as well, if they don't, you
can choose any
> arbitrary figure like "1234" or "1" or "69".

But where do i configure the SPC then?

>
>>
>> but I don't know what should I provide to him.
>> I think the OPC similar to our SPC, And the Link type is 64k,
>> But for TS and SLC, I don't know what to say.
>
>
> TS is the timeslot/chan on which you will send signalling. On each E1 you
have 31 TS.
> Normally 16 is used, although you can use any 1 to 31.
>
> Use SLC=0 for the first link.
>

Thanks  a lot, shokran, merci, gratci.

Regards,
--
Benaiad

>
>
>
>
> --
> wasim h. baig | principal consultant | convergence pk | +92 30 0850 8070 |
peace be upon you
--