>Just my guess:

>None of the spans (ports) is configured to provide clock to the other
>side. 

>If you want to cross-connect port 1 and port 2, you should use something
>like:

>span=1,1,4,ccs,hdb3,crc4
>span=2,0,4,ccs,hdb3,crc4

>(And run ztcfg after that)

Yes i know. The NT System is providing the clock. So i must not define a timing 
source on the NT System.
But even when i try your guess. The result is the same. 

I have played with all kind of configtypes. Nothing will work. 

The Joke is. When i plug my cross into the rhino card in TE mode. An use my 
config Span=1,0,4,etc. on the E400P they will sync.