2008/5/2 Tzafrir Cohen <[EMAIL PROTECTED]>: > On Fri, May 02, 2008 at 09:06:01AM +0200, Vinz486 wrote: > > 2008/4/30 Tzafrir Cohen <[EMAIL PROTECTED]>: > > > On Wed, Apr 30, 2008 at 09:07:48PM +0200, Vinz486 wrote: > > > > > --------------------------------------------------------------------------------------------------------- > > [May 2 08:51:00] WARNING[5119]: chan_zap.c:6685 handle_init_event: > > Detected alarm on channel 3: No Alarm > > [May 2 08:51:03] NOTICE[5119]: chan_zap.c:6678 handle_init_event: > > Alarm cleared on channel 4 > > > --------------------------------------------------------------------------------------------------------- > > This means that you should be able to see it in the InAlarm: field in > 'zap show channel 3' >
Ok. Made some experiments. InAlarm field show 1 if cable unplugged *BUT* only if in previouos time cable was plugged. In few words, at boot, InAlarm is 0, Cable plugged: 0, Cable unplugged: 1 If i use this field, after a boot without cable, my software will think that the cable is plugged. I found another useful field: Hookstate (FXS only). It tell me if the cable is plugged ever after a boot without cable. Hookstate (FXS only): Offhook <------Cable plugged Hookstate (FXS only): Onhook <------Cable unplugged I hope this can help other people (and make to think at Zaptel developing to insert a field exactly for this purpose, eg: Cable: plugged or Cable: unplugged). Bye. -- PicoStreamer - the real WEB live streaming software vinz486.com _______________________________________________ -- Bandwidth and Colocation Provided by http://www.api-digital.com -- asterisk-users mailing list To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users