Hi All - I pulled from a working system a TDM400 with one s110 fxs and three x100 fxos. I put it into a new box and the fxs no longer works. The fxos work just fine. I thought it was odd, but I chalked it up to a random chance failure and ordered another s110. The replacement doesn't work either, and now I'm confused.
dahdi_scan recognizes the s110, but it says it fails. Output looks like this: [2] active=yes alarms=OK description=Wildcard TDM400P REV E/F Board 5 name=WCTDM/4 manufacturer=Digium devicetype=Wildcard TDM400P REV E/F location=PCI Bus 05 Slot 01 basechan=5 totchans=4 irq=169 type=analog port=5,FXO port=6,FXO port=7,FXO port=8,FXS FAILED I tried moving both the s110s to other positions on the TDM400, but it fails in all of them. Is this a power issue? The system it's in only has sata power connectors, so I had to splice on an ide power connector. Both the 5v and 12v lines are connected through all the way from the power supply to the tdm400 card. If I force the issue, and manually configure the s110 like this: --------------- fxoks=8 echocanceller=mg2,8 --------------- the dahdi startup script throws this error: Running dahdi_cfg: DAHDI_CHANCONFIG failed on channel 8: Invalid argument (22) Selected signaling not supported Possible causes: FXO signaling is being used on a FXO interface (use a FXS signaling variant) RBS signaling is being used on a E1 CCS span Signaling is being assigned to channel 16 of an E1 CAS span Have I bungled the power connection and/or the config, or am I just extremely unlucky and have two bad s110s? Thanks, Noah -- _____________________________________________________________________ -- Bandwidth and Colocation Provided by http://www.api-digital.com -- New to Asterisk? Join us for a live introductory webinar every Thurs: http://www.asterisk.org/hello asterisk-users mailing list To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users