I have finally set correctly the Message Wait Indicator feature on my Grandstream (I was using the wrong context – I thought the documentation referred to the {[EMAIL PROTECTED] extension context not the voicemail context).

 

 

Voicemail.conf

[internalvoicemail]

 

20 => 1111,dean,[EMAIL PROTECTED],,attach=yes

30 => 2222,jodie,[EMAIL PROTECTED],,attach=yes

 

Sip.conf

[20]                                           ; Deans extension

type=friend                                ; This device takes and makes calls

username=20                            ; Username on device

secret=password                       ; Password for device

host=dynamic                            ; This host is not on the same IP addr every time

context=from-internal                  ; Inbound calls from this host go here

mailbox=20@internalvoicemail    ; Activate the message waiting light if this voicemailbox has messages in it

 

 

 

 

Anyway happy it’s all working, but when a voicemail message is left and MWI kicks in, the whole LCD display on the Grandstream flickers on and off not just the message wait light.
Not that this is a problem but is there some way to make it that the message light only flickers on and off.

 

Cheers,

Dean

 

Reply via email to