On Thu, Feb 05, 2009 at 11:06:59PM +0200, Nick Kossifidis wrote:
> I think this is because we call reset too many times. Try removing
> call to reset from config_interface, after some tests i did it seems
> wrong (we don't need to reset pcu and if we do, we don't need to reset
> the whole chip and re run phy initialization etc). I don't get any
> problems with ar2425 but i didn't get any before anyway (i never got a
> hang, just a few bmiss interrupts, not a storm).

Yep, with BMISS interrupts turned off and config_interface no longer 
calling reset, it's quite stable now.  Maybe there was some timing 
thing at play.  If we add a patch to remove those then I'm satisfied :)

-- 