any thoughts on this folk? On Tue, May 11, 2010 at 3:21 PM, Rakesh Kumar <gopchand...@gmail.com> wrote:
> According 802.11n standard, when using an A-MPDU, there is a PPDU duration > constraint of 10 ms. In ath9k, the function ath_tx_form_aggr in xmit.c > limits the duration of each A-MPDU to 4ms by computing the duration > corresponding to the intended rate to b used. > > In my previous discussion on this list, it was clarified that every A-MPDU > is somehow represented in two chains of ath_bufs of half the size. I just > wonder why 4 ms limit has been imposed instead of 10 ms? Is it because that > it is on one of the two 'parts' of the 'actual' aggregate that will be > ultimately transmitted? > > -- > Rakesh >