A vote here for the APC units. I've got a number deployed, both in Data Centres and much further afield, and aside from a firmware bug a few years back they've been quite solid.
I've also heard good things about the Raritan units (http://assets.raritan.com/resources/data_sheets/raritan-ds-rack-transfer-switch.pdf) and the Eaton units (https://powerquality.eaton.com/australia/products-services/power-distribution/au-ats.asp), but have never used one personally. Regards, -Brad. ________________________________________ From: AusNOG <ausnog-boun...@lists.ausnog.net> on behalf of Tony de Francesco <to...@pue.com.au> Sent: Wednesday, 8 November 2017 7:57 AM To: Mark Foster; Andrew Yager Cc: ausnog@lists.ausnog.net Subject: Re: [AusNOG] ATS vs STS & recommendations? We've had clients using this micro-ATS: http://www.zonit.com/products/micro-ats/ If you need pricing and availability contact PiTek: http://www.pitek.com.au/contact Kind Regards Tony de Francesco -----Original Message----- From: AusNOG [mailto:ausnog-boun...@lists.ausnog.net] On Behalf Of Mark Foster Sent: Wednesday, 8 November 2017 10:37 AM To: Andrew Yager <and...@rwts.com.au> Cc: ausnog@lists.ausnog.net Subject: Re: [AusNOG] ATS vs STS & recommendations? Previously deployed this one: http://www.dynamix.net.au/index.html?do=viewproduct&code=RP-ATS&ID=7842286 3 (Dynamix RP-ATS) Had no problems - but only limited exposure to it's actual performance 'under fire' as our power supply was pretty reliable. APC (Schneider Electric) have a range of their own. http://www.apc.com/shop/nz/en/categories/power-distribution/transfer-switc hes/rack-mount-transfer-switches/_/N-1eg32mv Mark. > Hi All, > > One of our DC providers is removing some power from a single feed in > some of our racks soon, and a couple of our customers have some single > fed units that are connected to the "wrong" rail. > > We are looking to help them out with ATS or STSs. I remember some > discussion some time ago about whether one is better than the other, > and some quite technical arguments why you would prefer one or the other. > > For a standard 10A outlet and a 500-1kw load what do people recommend > these days? > > Thanks, > Andrew > > Get Outlook for iOS<https://aka.ms/o0ukef> > _______________________________________________ > AusNOG mailing list > AusNOG@lists.ausnog.net > http://lists.ausnog.net/mailman/listinfo/ausnog > _______________________________________________ AusNOG mailing list AusNOG@lists.ausnog.net http://lists.ausnog.net/mailman/listinfo/ausnog _______________________________________________ AusNOG mailing list AusNOG@lists.ausnog.net http://lists.ausnog.net/mailman/listinfo/ausnog _______________________________________________ AusNOG mailing list AusNOG@lists.ausnog.net http://lists.ausnog.net/mailman/listinfo/ausnog