Delete the *.aoi file, which is the object index. Once you start Ax afterwards, a new index will be generated. This should help. /Jens
_____ From: Axapta-Knowledge-Village@yahoogroups.com [mailto:axapta-knowledge-vill...@yahoogroups.com] On Behalf Of Pankaj Kant Sent: Thursday, October 29, 2009 3:48 PM To: Axapta-Knowledge-Village@yahoogroups.com Subject: [Axapta-Knowledge-Village] Objects are not refreshed in Production server. Hi, We are facing a peculiar issue as Objects are not refreshed in Production server. Request your inputs on the issue below: Environment: AX 4.0 SP1 Issue: Refreshing of objects in Ax. After importing the objects into production environment in traditional way which involved disconnect all the users from the server, import the objects, restart the AOS, compile whole application. But we are facing refresh issues with some of the users' environments. To eradicate this we deleted the 'usage data' and restart the services. Even after this effort, still we are facing the problem. Your suggestions in this regards are highly appreciated. Best regards Pankaj Kant