https://issues.apache.org/jira/browse/AXIS2C-545?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Damitha Kumarage resolved AXIS2C-545.
-------------------------------------
Resolution: Fixed
Assignee: Damitha Kumarage
I just set a property AXIS2_HANDLER_ALREADY_VISITED after the incoming phases
are passed from sandesha2c. So in mep_client I can check this property and
avoid passing to the engine_receive again. Instead just return the response
message context
> Sandesha2 in handler is called twice
> ------------------------------------
>
> Key: AXIS2C-545
> URL: https://issues.apache.org/jira/browse/AXIS2C-545
> Project: Axis2-C
> Issue Type: Bug
> Reporter: Damitha Kumarage
> Assigned To: Damitha Kumarage
> Attachments: mep_client.c.diff
>
>
> In RM 1.0 two way single channel scenario when it come to mep_client's
> engine_two_way_send function's engine_receive call the
> sandesha2_global_in_handler is already visited. So when engine_receive is
> called sandesha2_global_in_handler will be called twice. RM 1. 0 two way
> single channel implementation is a hack in sandesha2c to allow to do two way
> messaging in a single channel in RM. As a result this kind of unexpected
> difficulties arise. As a solution I can set a property
> SANDESHA2_HANDLER_ALREADY_VISITED in axis2_msg_ctx when the global in
> handler is visited once. So I can check this property from global_in_handler
> when it is visted again in the same response channel. To do that I need to do
> a small change
> in mep_client.c The changes is that I need to get the property map from
> msg_ctx and set it in response.
> If anybody see a better solution please let me know.
--
This message is automatically generated by JIRA.
-
You can reply to this email to add a comment to the issue online.
---------------------------------------------------------------------
To unsubscribe, e-mail: [EMAIL PROTECTED]
For additional commands, e-mail: [EMAIL PROTECTED]