Hello Dirk,

As I mentioned some time ago, when I do a "status slots" in the bat command 
line and my storage device is defined to be an autochanger, in the ensuing 
communications between the director and bat, the director issues a:

Enter autochanger drive[0]:

and at that point, bat gets totally confused.  Instead of doing a prompt, it 
starts up a new connection to the Director, which is useless, and all the 
rest of the output from the command is lost.

The full debug output is:

bat: bcomm/dircomm.cpp:246 conn 1 send: status slots
bat: console/console.cpp:597 DisplaytoPrompt roxie-dir
bat: bcomm/dircomm.cpp:321 conn 1 CMD BEGIN
bat: bcomm/dircomm.cpp:292 conn 1 got: Automatically selected Storage: 
LTO-changer

bat: bcomm/dircomm.cpp:292 conn 1 got: Enter autochanger drive[0]:
bat: bcomm/dircomm.cpp:335 conn 1 PROMPT
bat: console/console.cpp:609 endDisplaytoPrompt=-1 roxie-dir
bat: mainwin.cpp:322 Exiting Wait State
bat: bcomm/dircomm.cpp:446 m_notifier Enabling notifier: 1 roxie-dir
bat: console/console.cpp:814 DirComm 2 About to Create and Connect roxie-dir
bat: bcomm/dircomm.cpp:246 conn 2 send: .api 1
bat: console/console.cpp:597 DisplaytoPrompt roxie-dir
bat: bcomm/dircomm.cpp:310 conn 2 CMD OK
bat: bcomm/dircomm.cpp:329 conn 2 MAIN PROMPT
bat: console/console.cpp:609 endDisplaytoPrompt=-1 roxie-dir
bat: bcomm/dircomm.cpp:246 conn 2 send: .
bat: bcomm/dircomm.cpp:321 conn 2 CMD BEGIN
bat: bcomm/dircomm.cpp:310 conn 2 CMD OK
bat: bcomm/dircomm.cpp:329 conn 2 MAIN PROMPT
bat: bcomm/dircomm.cpp:212 Returning TRUE from DirComm->connect_dir : 2 
roxie-dir
bat: console/console.cpp:820 DirComm 2 Connected roxie-dir
bat: bcomm/dircomm.cpp:69 DirComm 0 terminating connections roxie-dir
bat: bcomm/dircomm.cpp:69 DirComm 1 terminating connections roxie-dir
bat: bcomm/dircomm.cpp:69 DirComm 2 terminating connections roxie-dir

Notice, how just after the PROMPT it starts a second connection.

We are about to release Bacula version 3.0.2, and I would really like to have 
this fixed.  I believe that the same thing happens if there are multiple 
Storage devices defined and the user must select among them.

Can you help point out to me what needs to be fixed to keep bat from opening a 
second connection?

Best regards,

Kern

------------------------------------------------------------------------------
Enter the BlackBerry Developer Challenge  
This is your chance to win up to $100,000 in prizes! For a limited time, 
vendors submitting new applications to BlackBerry App World(TM) will have
the opportunity to enter the BlackBerry Developer Challenge. See full prize  
details at: http://p.sf.net/sfu/Challenge
_______________________________________________
Bacula-devel mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/bacula-devel

Reply via email to