Hello everybody,


I use Bacula 1.38.2 whith HP SSL 1016 Autoloader.

SD Config:

# This is the definition for a
#   HP SSL1016 Ultrium 460 Autoloader
#
Autochanger {
  Name = HP-Library
  Device = HP-SSL1016
  Changer Device = /dev/sg2
  Changer Command = "/usr/local/bacula-1.38.3/etc/mtx-changer %c %o %S %a %d"
}



Device {
  Name = HP-SSL1016
  Media Type = LTO2
  Archive Device = /dev/nst0
# Changer Command = "/usr/local/bacula-1.38.3/etc/mtx-changer %c %o %S %a %d"
  AutoChanger = yes
  #Autoselect = yes;
  AutomaticMount = yes;               # when device opened, read it
  LabelMedia = yes;
  AlwaysOpen = yes;
}

DIR Config:

JobDefs {
  Name = "Week-backup"
  Type = Backup
  Level = Full
  Client = nas01-fd
  FileSet = "Weekly Full Set"
  Schedule = "WeeklyCycle"
  RunBeforeJob = "/usr/local/sbin/tape clean"
  RunAfter Job =  "/usr/local/sbin/tape unload"
  Storage = HP-Library
  Messages = Standard
  Pool = WocheWochensicherung
  Priority = 10
}





Then I tried to run a Backup.
The mtx-changer scripts works fine.
But bacula dosent load the tapes.
The command "update slots" ends up in an error "No slots in changer to scan"

Any hints what went wrong?






Many thank in advanced.

Reply via email to