On Sun, Mar 12, 2006 at 02:05:15PM -0500, Dave wrote:
> Hello,
>    I've got some new dlt tapes that were given to me. Before i put them in 
> to production i'd like to fully clear them and ensure they're good to work 
> with bacula. I'm getting an error that the tape in question is not in the 
> catalog, which is correct it isn't, it's new to bacula, yet it already has 
> a label on it from it's previous place of work.
>    Thanks.
> Dave.
While bacula-sd is off:
mt -f <device> rewind
mt -f <device> weof
to clear the label.

See
http://www.bacula.org/rel-manual/Volume_Utility_Tools.html#SECTION000369100000000000000
on how to test your tape.

-Jason Martin
-- 
I'm so broke, I can't even pay attention.
This message is PGP/MIME signed.

Attachment: pgpddO3Iq7eMi.pgp
Description: PGP signature