On Thursday 14 September 2006 05:01 pm, Jack wrote: > I have been using bacula for over six months now to dump backups to > disk. I have recently aquired a EZ17 autoloader with the AIT2 tape drive > in it (a SDX500 if I'm not mistaken). > ... > *mount > ... > 3301 Issuing autochanger "loaded drive 0" command. > 3302 Autochanger "loaded drive 0", result is Slot 2. > block.c:944 Read error at file:blk 0:0 on device "SDX500" (/dev/nst0). > ERR=Input/output error. > block.c:944 Read error at file:blk 0:0 on device "SDX500" (/dev/nst0). > ERR=Input/output error.
This appears to be a problem with device permissions rather than bacula. What are the permissions on /dev/nst0? Does the user under which you are running bacula have sufficient permissions? Have you run the tape drive verification procedure in the bacula manual? Perhaps you have and I am coming in late on a thread, ignore if you've done all this. -- -- Michael ------------------------------------------------------------------------- Using Tomcat but need to do more? Need to support web services, security? Get stuff done quickly with pre-integrated technology to make your job easier Download IBM WebSphere Application Server v.1.0.1 based on Apache Geronimo http://sel.as-us.falkag.net/sel?cmd=lnk&kid=120709&bid=263057&dat=121642 _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users