Hi - I'm trying to determine a reasonable base before moving onto Bacula itself... have a look at this, does it make sense?
The autoloader starts off empty. I use mtx to load a tape, and even this trivial operation returns an error, yet the tape has definately moved! The autoloader already has the latest firmware :( [EMAIL PROTECTED] bacula]# mtx -f /dev/sg3 inquiry Product Type: Medium Changer Vendor ID: 'HP ' Product ID: '1x8 G2 AUTOLDR ' Revision: '1.30' Attached Changer API: No [EMAIL PROTECTED] bacula]# mtx -f /dev/sg3 status Storage Changer /dev/sg3:1 Drives, 8 Slots ( 0 Import/Export ) Data Transfer Element 0:Empty Storage Element 1:Full :VolumeTag=VHJ252L2 Storage Element 2:Full :VolumeTag=VHJ251L2 Storage Element 3:Full :VolumeTag=VHJ239L2 Storage Element 4:Full :VolumeTag=VHJ250L2 Storage Element 5:Full :VolumeTag=VHJ246L2 Storage Element 6:Full :VolumeTag=VHJ247L2 Storage Element 7:Full :VolumeTag=VHJ248L2 Storage Element 8:Full :VolumeTag=VHJ249L2 [EMAIL PROTECTED] bacula]# mtx -f /dev/sg3 load 1 Loading media from Storage Element 1 into drive 0... (.. 15 seconds pass... ) mtx: Request Sense: Long Report=yes mtx: Request Sense: Valid Residual=no mtx: Request Sense: Error Code=0 (Unknown?!) mtx: Request Sense: Sense Key=No Sense mtx: Request Sense: FileMark=no mtx: Request Sense: EOM=no mtx: Request Sense: ILI=no mtx: Request Sense: Additional Sense Code = 00 mtx: Request Sense: Additional Sense Qualifier = 00 mtx: Request Sense: BPV=no mtx: Request Sense: Error in CDB=no mtx: Request Sense: SKSV=no MOVE MEDIUM from Element Address 1001 to 1 Failed [EMAIL PROTECTED] bacula]# echo $? 1 [EMAIL PROTECTED] bacula]# mtx -f /dev/sg3 status mtx: Request Sense: Long Report=yes mtx: Request Sense: Valid Residual=no mtx: Request Sense: Error Code=70 (Current) mtx: Request Sense: Sense Key=Unit Attention mtx: Request Sense: FileMark=no mtx: Request Sense: EOM=no mtx: Request Sense: ILI=no mtx: Request Sense: Additional Sense Code = 28 mtx: Request Sense: Additional Sense Qualifier = 00 mtx: Request Sense: BPV=no mtx: Request Sense: Error in CDB=no mtx: Request Sense: SKSV=no Mode sense (0x1A) for Page 0x1D failed Storage Changer /dev/sg3:1 Drives, 8 Slots ( 0 Import/Export ) Data Transfer Element 0:Full (Storage Element 1 Loaded):VolumeTag = VHJ252L2 Storage Element 1:Empty Storage Element 2:Full :VolumeTag=VHJ251L2 Storage Element 3:Full :VolumeTag=VHJ239L2 Storage Element 4:Full :VolumeTag=VHJ250L2 Storage Element 5:Full :VolumeTag=VHJ246L2 Storage Element 6:Full :VolumeTag=VHJ247L2 Storage Element 7:Full :VolumeTag=VHJ248L2 Storage Element 8:Full :VolumeTag=VHJ249L2 OS is CentOS 4.5 with all updates applied. Cheers, Gavin. ------------------------------------------------------------------------- This SF.net email is sponsored by: Splunk Inc. Still grepping through log files to find problems? Stop. Now Search log events and configuration files using AJAX and a browser. Download your FREE copy of Splunk now >> http://get.splunk.com/ _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users