Michael Galloway schrieb:
> Wrote blk_block=3465000, dev_blk_num=9000 VolBytes=223,534,015,488 
> rate=38171.8 KB/s
> Wrote blk_block=3470000, dev_blk_num=14000 VolBytes=223,856,575,488 
> rate=38194.3 KB/s
> Wrote blk_block=3475000, dev_blk_num=3500 VolBytes=224,179,135,488 
> rate=38184.1 KB/s
> 
> 38MB/s is only around 140GB/hr. i'd expect a bit more from LTO-4. 

I get ~77 MB/s with a HP Ultrium LTP-4 drive during full backups and
spooling (write speed to tape).

> > > target5:0:15: Beginning Domain Validation
> > > target5:0:15: Domain Validation skipping write tests
> > > target5:0:15: Ending Domain Validation
> > > target5:0:15: FAST-80 WIDE SCSI 160.0 MB/s DT (12.5 ns, offset 126)
> > > target5:0:15: Beginning Domain Validation
> > > target5:0:15: Domain Validation skipping write tests
> > > target5:0:15: Ending Domain Validation
> > > target5:0:15: FAST-80 WIDE SCSI 160.0 MB/s DT (12.5 ns, offset 126)
> > > target5:0:15: Beginning Domain Validation
> > > target5:0:15: Domain Validation skipping write tests
> > > target5:0:15: Ending Domain Validation
> > > target5:0:15: FAST-80 WIDE SCSI 160.0 MB/s DT (12.5 ns, offset 126)
> > > target5:0:15: Beginning Domain Validation
> > > target5:0:15: Domain Validation skipping write tests
> > > target5:0:15: Ending Domain Validation
> > > target5:0:15: FAST-80 WIDE SCSI 160.0 MB/s DT (12.5 ns, offset 126)

I don't see the errors you get. But I also see "FAST-80 WIDE SCSI
160.0 MB/s" mesages in my kernel log. The HP tool ltt reports U160
connections for both of my drives.  Altough the scsi controller's bios
claims during boot that the drives are connected with U320 and the
drives are capable of U320.

After boot I checked the scsi paramters and it looks like 6.25 would be
the correct value for U320. But the HP tool still shows that the
drives are connected with U160. 

/sys/class/spi_transport/target5\:0\:1/min_period 
6.25

Sorry for hijacking one half of your thread, but I would like to know
if anyone has seen a FAST-160 message in the kernel log with tape
drives.  Not that I could saturate a U160 connection, but I would like
to know why it's only connecting with U160 speed. An other LSI
controller which is used for a RAID devices shows the propper U320
(FAST-160) value during boot.

Ralf

-------------------------------------------------------------------------
This SF.net email is sponsored by: Splunk Inc.
Still grepping through log files to find problems?  Stop.
Now Search log events and configuration files using AJAX and a browser.
Download your FREE copy of Splunk now >> http://get.splunk.com/
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to