I have a problem running an AUTOCHANGER as a part of backup system. Tape is: Product Type: Tape Drive Vendor ID: 'HP' Product ID: 'Ultrium 3-SCSI' Revision: 'G36Z' and everything else looks like to work fine, except of the autochanger: Product Type: Medium Changer Vendor ID: 'QUANTUM' Product ID: 'UHDL' Revision: '0031' Both of them are part of one device: StorEdge C2 (from SUN Microsystems), model: SQL700 . Connected through: SCSI storage controller: LSI Logic / Symbios Logic 53c1030 PCI-X Fusion-MPT Dual Ultra320 SCSI (rev 08)
After running the 'mtx -f /dev/sg3 status' i get this result: Storage Changer /dev/sg3:1 Drives, 16 Slots ( 0 Import/Export ) Data Transfer Element 0:Full (Unknown Storage Element Loaded) ... Storage Element 16:Full When executed this './mtx-changer /dev/sg3 load 1 /dev/nst0 0', i just received this response: Drive 0 Full (Storage Element 0 loaded) And finally when tryied this command (from the Bacula's manual chapter of testing the tape drive): 'btape -c /etc/bacula/bacula-sd.conf /dev/nst0' , i just get this ERROR msg: === Autochanger test === 3301 Issuing autochanger "loaded" command. Nothing loaded in the drive. OK. 3303 Issuing autochanger "load 1 0" command. 3993 Bad autochanger command: /etc/bacula/scripts/mtx-changer /dev/sg3 load 1 /dev/nst0 0 3993 result="Drive 0 Full (Storage Element 0 loaded)": ERR=Child exited with code 1 You must correct this error or the Autochanger will not work. Could anybody give me some help please? Thanks in advance for any hint. Daniel ------------------------------------------------------------------------------ _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users