On Saturday 18 October 2014 11:01:28 Ana Emília M. Arruda wrote:
> Just a comment here. Since you have "volume use duration = 7 days" and your
> volume was used until 12:58 next day, I'm quite sure (don't know how is
> your schedule configured) that this volume will be available (append) for
> use in the next week by your backup jobs. Because of your "volume use
> duration" configuration, Bacula started to use the same volume two weeks
> sequentially.
> 
> 13-Oct 21:08 bl13-sd JobId 1761: Committing spooled data to Volume
> "000529L4". Despooling 7,153,238,703 bytes ...
> 14-Oct 12:58 bl13-sd JobId 1761: Despooling elapsed time = 00:01:06,
> Transfer rate = 108.3 M Bytes/second
> 14-Oct 12:58 bl13-sd JobId 1761: Elapsed time=15:55:43, Transfer rate=124.6
> K Bytes/second
> 14-Oct 12:58 bl13-sd JobId 1761: Alert: TapeAlert: OK
> 14-Oct 12:58 bl13-sd JobId 1761: Sending spooled attrs to the Director.
> Despooling 37,665 bytes ...
> 14-Oct 12:58 bl13-dir JobId 1761: Bacula bl13-dir 5.2.13 (19Jan13):
> 
> Do you have prefer mounted volume set to yes?
> 
> Regards,
> Ana
It didn't used the volume incorrectly recyled, 000529L4,
bacula storage daemon just recycled it, marked as used 
and proceeded, correctly to backup on 000506L4 after
a manual intervention.

The manual intervention was required because the volume
000506L4 for some reason I don't quite understand was 
not considered anymore inside the changer (it was of course),
as this log, from another concurrent job show

13-Oct 21:00 bl13-dir JobId 1762: Start Backup JobId 1762, 
Job=MccwHome.2014-10-13_21.00.00_34
13-Oct 21:01 bl13-dir JobId 1762: Using Device "lto1" to write.
13-Oct 21:01 bl13-dir JobId 1762: Sending Accurate information.
13-Oct 21:02 bl13-sd JobId 1762: No slot defined in catalog (slot=0) for Volume 
"000506L4" on "lto1" (/dev/nlto1).
13-Oct 21:02 bl13-sd JobId 1762: Cartridge change or "update slots" may be 
required.
13-Oct 21:02 bl13-sd JobId 1762: Warning: Director wanted Volume "000506L4".
    Current Volume "000529L4" not acceptable because:
    1998 Volume "000529L4" catalog status is Used, but should be Append, Purged 
or Recycle.
13-Oct 21:02 bl13-sd JobId 1762: 3307 Issuing autochanger "unload slot 4, drive 
1" command.
13-Oct 21:03 bl13-sd JobId 1762: No slot defined in catalog (slot=0) for Volume 
"000506L4" on "lto1" (/dev/nlto1).
13-Oct 21:03 bl13-sd JobId 1762: Cartridge change or "update slots" may be 
required.

After the intervention, "update slots", the jobs continued without
any problem

14-Oct 12:58 bl13-sd JobId 1761: Despooling elapsed time = 00:01:06, Transfer 
rate = 108.3 M Bytes/second
14-Oct 12:58 bl13-sd JobId 1761: Elapsed time=15:55:43, Transfer rate=124.6 K 
Bytes/second
14-Oct 12:58 bl13-sd JobId 1761: Alert: TapeAlert: OK
14-Oct 12:58 bl13-sd JobId 1761: Sending spooled attrs to the Director. 
Despooling 37,665 bytes ...
14-Oct 12:58 bl13-dir JobId 1761: Bacula bl13-dir 5.2.13 (19Jan13):

14-Oct 12:56 bl13-sd JobId 1762: 3304 Issuing autochanger "load slot 9, drive 
1" command.
14-Oct 12:56 bl13-sd JobId 1762: 3305 Autochanger "load slot 9, drive 1", 
status is OK.
14-Oct 12:56 bl13-sd JobId 1762: Recycled volume "000506L4" on device "lto1" 
(/dev/nlto1), all previous data lost.

And yes, I've "prefer mounted volume set to yes" for these jobs.

G. Vitillaro.

------------------------------------------------------------------------------
Comprehensive Server Monitoring with Site24x7.
Monitor 10 servers for $9/Month.
Get alerted through email, SMS, voice calls or mobile push notifications.
Take corrective actions from your mobile device.
http://p.sf.net/sfu/Zoho
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to