Hello- Is there a trick to using Bacula with LTO hardware encryption enabled?
With drive encryption turned on, verify jobs are hitting an I/O error reading the first record of a tape file. On a test job that went to files 78, 79 and 80, the error looks like this: 19-Oct 14:03 ccnback-sd JobId 988: Ready to read from volume "CCNB12" on tape device "Magnum-224-LTO4" (/dev/tape/by-id/scsi-1IBM_ULTRIUM-TD4_1310025811-nst). 19-Oct 14:03 ccnback-sd JobId 988: Forward spacing Volume "CCNB12" to file:block 78:0. 19-Oct 14:19 ccnback-sd JobId 988: Error: block.c:429 Read error on fd=5 at file:blk 79:0 on device "Magnum-224-LTO4" (/dev/tape/by-id/scsi-1IBM_ULTRIUM-TD4_1310025811-nst). ERR=Input/output error. 19-Oct 14:19 ccnback-sd JobId 988: End of Volume at file 79 on device "Magnum-224-LTO4" (/dev/tape/by-id/scsi-1IBM_ULTRIUM-TD4_1310025811-nst), Volume “CCNB12" dd can read the data from both files. The boundary is on the phrase "varius sed feugiat”. The end of file 78, and the start of 79 are: "varius sed " "~\274\301\214^@^@\374^@^@^A.\300BB02^@^@^@^AV%X\226^@^@^@3\377\377\377\376^@^@\313\233feugiat” I’m using Bacula 7.0.5 with an LTO-4 drive and stenc 1.0.7 to control encryption. Any advice would be appreciated. Thank you very much. Mark ------------------------------------------------------------------------------ _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users