Hello,
2018-07-17 13:57 GMT+02:00 Christoph Litauer <[email protected]>:
> Maybe the problem is that both libraries are of type LTO6?
>
>
I think this is a main issue here. All your devices have MediaType=LTO6
which tells Bacula it can use any drive with any volume which has the same
MediaType parameter set. This is the only parameter which allows Bacula to
distinguish tape/drive physical separation. All you need is to change the
configuration and manual update the media type for volumes in catalog.
best regards
--
Radosław Korzeniewski
[email protected]
------------------------------------------------------------------------------