Hello Marcin,

> Le 10 août 2026 à 08:49, Marcin Haba <[email protected]> a écrit :
> 
> Hello Eric,
> 
> That is really great news. Congratulations to everybody involved in
> changes for this beta release.
> 
> Today I am starting tests with 17.0.0. For now I found a few problems
> described below.
> 
> On Fri, 7 Aug 2026 at 10:31, eric--- via Bacula-devel
> <[email protected]> wrote:
>> 
>> Some default behaviors have changed since the previous version:
>> - The DirectoryACL and UidAcl Console ACL directives can now be left unset, 
>> rather than being set to *all*
> 
> This directive is named UserIdAcl, not UidAcl.
> 
>> - The Storage Daemon Device/SyncOnClose directive is now enabled by default
> 
> This Device/SyncOnClose directive is enabled by default already in
> Bacula version 15.0.
> 

Thanks for the feedback, I will fix the file.

>> https://www.bacula.org/downloads/Bacula-17.0.0/ReleaseNotes
> 
> In ReleaseNotes 17.0.0 are listed changes for Baculum from version 15.0.
> 
> Please let me know before new releases, the same as we were doing it
> in the past. This way I know when repo is ready to add changes and I
> have a chance to prepare Baculum for the new version. Thanks in
> advance.
> 

I sent you a message last week, but I have used your bacula.pl email address 
and I got no error or reply, I will use the gmail one now.

> This Baculum 17.0.0 is not adapted for Bacula 17.0.0. I will check it
> together with the Bacula 17.0.0 tests.

No problem, this is a beta release, ping me when your tests are done.

Best Regards,
Eric



_______________________________________________
Bacula-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to