On Tue, Jun 21, 2022 at 12:15:29PM +0200, Robin van der Gracht wrote:
> A DMA cmd + data transfer can finish or stop (i.e. on a block gap) before
> the status register is cleared. In that case we'll lose track of state
> causing sdhci_transfer_data_dma() to loop forever waiting for status bits
> that are already cleared.
> 
> Clearing SDHCI_INT_CMD_COMPLETE should suffice here. Since it's not
> evaluated a second time, clearing it at the start of the function is
> sufficient so we can just remove the erroneous status write.
> 
> Signed-off-by: Robin van der Gracht <ro...@protonic.nl>
> ---
>  drivers/mci/imx-esdhc-common.c | 1 -
>  1 file changed, 1 deletion(-)

Applied to master, thanks

Sascha

> 
> diff --git a/drivers/mci/imx-esdhc-common.c b/drivers/mci/imx-esdhc-common.c
> index a12db43c88..27293e44b7 100644
> --- a/drivers/mci/imx-esdhc-common.c
> +++ b/drivers/mci/imx-esdhc-common.c
> @@ -176,7 +176,6 @@ int __esdhc_send_cmd(struct fsl_esdhc_host *host, struct 
> mci_cmd *cmd,
>       }
>  
>       irqstat = sdhci_read32(&host->sdhci, SDHCI_INT_STATUS);
> -     sdhci_write32(&host->sdhci, SDHCI_INT_STATUS, irqstat);
>  
>       if (irqstat & CMD_ERR)
>               return -EIO;
> -- 
> 2.34.1
> 
> 

-- 
Pengutronix e.K.                           |                             |
Steuerwalder Str. 21                       | http://www.pengutronix.de/  |
31137 Hildesheim, Germany                  | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |