Some phys registered from devicetree have pinctrl settings attached to
them. Configure the pinctrl state to make sure they can be accessed
before trying to reset and detect the phy devices.

Signed-off-by: Sascha Hauer <s.ha...@pengutronix.de>
---
 drivers/net/phy/mdio_bus.c | 2 ++
 1 file changed, 2 insertions(+)

diff --git a/drivers/net/phy/mdio_bus.c b/drivers/net/phy/mdio_bus.c
index 99d23ffedf..e37ab79f3e 100644
--- a/drivers/net/phy/mdio_bus.c
+++ b/drivers/net/phy/mdio_bus.c
@@ -22,6 +22,7 @@
 #include <linux/phy.h>
 #include <linux/err.h>
 #include <of_device.h>
+#include <pinctrl.h>
 
 #define DEFAULT_GPIO_RESET_ASSERT       1000      /* us */
 #define DEFAULT_GPIO_RESET_DEASSERT     1000      /* us */
@@ -202,6 +203,7 @@ static int of_mdiobus_register(struct mii_bus *mdio, struct 
device_node *np)
                        continue;
                }
 
+               of_pinctrl_select_state_default(child);
                of_mdiobus_reset_phy(mdio, child);
                of_mdiobus_register_phy(mdio, child, addr);
        }
-- 
2.30.2