On Thu, Nov 09, 2023 at 01:10:12PM +0100, Ahmad Fatoum wrote:
> On the STM32MP1, shutting down barebox can result in a
> 
>   ERROR: phy1: phy exit failed --> -22
> 
> message printed to the console. This is because the regulator is disabled
> more often than it was enabled, because stm32_usbphyc_pll_disable
> is called twice:
> 
>   - Once from stm32_usbphyc_remove calling stm32_usbphyc_phy_exit
>   - Once from dwc2_remove calling phy_exit -> stm32_usbphyc_phy_exit
> 
> The code is taken from Linux and likely causes no issues there, because
> devices are removed in reverse probe order, which barebox doesn't
> enforce. Properly solving this would be a larger endeavour, so for now
> just fix the stm32-usbphyc driver to ignore reference count dropping
> below zero and only call __stm32_usbphyc_pll_disable once.
> 
> Signed-off-by: Ahmad Fatoum <a.fat...@pengutronix.de>
> ---
>  drivers/phy/phy-stm32-usbphyc.c | 2 +-
>  1 file changed, 1 insertion(+), 1 deletion(-)

Applied, thanks

Sascha

> 
> diff --git a/drivers/phy/phy-stm32-usbphyc.c b/drivers/phy/phy-stm32-usbphyc.c
> index ac82b019f44c..91f4e7f7e08d 100644
> --- a/drivers/phy/phy-stm32-usbphyc.c
> +++ b/drivers/phy/phy-stm32-usbphyc.c
> @@ -277,7 +277,7 @@ static int __stm32_usbphyc_pll_disable(struct 
> stm32_usbphyc *usbphyc)
>  static int stm32_usbphyc_pll_disable(struct stm32_usbphyc *usbphyc)
>  {
>       /* Check if a phy port is still active or clk48 in use */
> -     if (atomic_dec_return(&usbphyc->n_pll_cons) > 0)
> +     if (atomic_dec_return(&usbphyc->n_pll_cons) != 1)
>               return 0;
>  
>       return __stm32_usbphyc_pll_disable(usbphyc);
> -- 
> 2.39.2
> 
> 
> 

-- 
Pengutronix e.K.                           |                             |
Steuerwalder Str. 21                       | http://www.pengutronix.de/  |
31137 Hildesheim, Germany                  | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |

Reply via email to