On 1/8/26 11:07 AM, Sascha Hauer wrote:
> When bootstrapping barebox on QEMU with my barebox-bringup utility it
> brings it to the 'barebox' state before opening a console. The
> BareboxDriver consumes all console messages in order to bring barebox
> to the prompt. This is bad for interactive use where one wants to
> see the console output right from the start.
>
> Insert a 'on' state which brings up QEMU but doesn't activate the
> BareboxDriver.
>
> Signed-off-by: Sascha Hauer <[email protected]>
Reviewed-by: Ahmad Fatoum <[email protected]>
> ---
> test/strategy.py | 15 +++++++++------
> 1 file changed, 9 insertions(+), 6 deletions(-)
>
> diff --git a/test/strategy.py b/test/strategy.py
> index 0f1b761474..0ca08b0cdd 100644
> --- a/test/strategy.py
> +++ b/test/strategy.py
> @@ -21,11 +21,12 @@ if match is None or int(match.group(1)) < 25:
> class Status(enum.Enum):
> unknown = 0
> off = 1
> - barebox = 2
> - qemu_dry_run = 3
> - qemu_interactive = 4
> - qemu_dump_dtb = 5
> - shell = 6
> + on = 2
> + barebox = 3
> + qemu_dry_run = 4
> + qemu_interactive = 5
> + qemu_dump_dtb = 6
> + shell = 7
>
>
> @target_factory.reg_driver
> @@ -63,11 +64,13 @@ class BareboxTestStrategy(Strategy):
> self.target.deactivate(self.console)
> self.target.activate(self.power)
> self.power.off()
> - elif status == Status.barebox:
> + elif status == Status.on:
> self.transition(Status.off) # pylint: disable=missing-kwoa
> self.target.activate(self.console)
> # cycle power
> self.power.cycle()
> + elif status == Status.barebox:
> + self.transition(Status.on) # pylint: disable=missing-kwoa
> # interrupt barebox
> self.target.activate(self.barebox)
> elif status == Status.shell:
--
Pengutronix e.K. | |